Material Application: Attaches metal to metal.
Recess Type:
Unslotted Indented Hex
Head Type:
Hex Washer Head
Coating:
Climaseal
Where to Buy:
Bulk Products
Size | Pt | Finish | Bulk Part No | Bulk Qty | Lbs.* |
Drill Cap (in.) |
10-16 x 3/4” | #3 | Climaseal | 1005000 | 3,000 | 27 | .036 – .175 |
10-16 x 1-1/2” | #3 | Climaseal | 1308000 | 2,500 | 33 | .036 – .175 |
12-14 x 3/4” | #3 | Climaseal | 1009000 | 3,000 | 31 | .036 – .210 |
12-14 x 1” | #3 | Climaseal | 1011000 | 3,000 | 37 | .036 – .210 |
12-14 x 2” | #3 | Climaseal | 1016000 | 1,500 | 28 | .036 – .210 |
12-14 x 3” | #3 | Climaseal | 1333000 | 1,000 | 26 | .036 – .210 |
1/4-14 x 1” | #3 | Climaseal | 1160000 | 2,500 | 44 | .036 – .210 |
1/4-14 x 1-1/4” | #3 | Climaseal | 1019000 | 2,000 | 41 | .036 – .210 |
1/4-14 x 2” | #3 | Climaseal | 1021000 | 1,000 | 27 | .036 – .210 |
*Carton weights are approximate and may vary.
Features
• Point has precise cutting edges to improve drill performance with less effort
• Non-walking point provides fast material engagement
• Point to thread design maximizes pullout performance and minimizes backout
• Drills and taps in the broadest range of applications
• Climaseal® finish provides excellent corrosion resistance and lower tapping torque
• Vulcanized bonding of washer eliminates separation of EPDM from the metal backing
• Dual sealing bonded washer prevents leaks
Test Results
Pullout Values (Avg. Lbs. Ultimate) | |||||||||
Fastener | Steel Gauge | ||||||||
Size | Pt | 26 | 24 | 22 | 20 | 18 | 16 | 14 | 12 |
10-16 | 3 | 124 | 208 | 266 | 299 | 499 | 708 | 967 | 1474 |
12-14 | 3 | 142 | 211 | 289 | 341 | 551 | 757 | 1063 | 1631 |
1/4-14 | 3 | 141 | 231 | 293 | 346 | 613 | 880 | 1145 | 1858 |
Shear Values (Avg. Lbs. Ultimate) | |||||||||
Fastener | Steel Gauge (Lapped) | ||||||||
Size | Pt | 26 | 24 | 22 | 20 | 18 | 16 | 14 | 12 |
10-16 | 3 | 455 | 526 | 728 | 1266 | 1540 | |||
12-14 | 3 | 769 | 1358 | 1620 | 1970 | 1986 | |||
1/4-14 | 3 | 930 | 1442 | 2100 | 2584 | 2650 | |||
The values listed are averages achieved under laboratory conditions and imply no warranty. Appropriate safety factors should be applied to these values for design purposes. |