selfdrillingheading

Phillips Flat Head, Zinc Plated

Material Application: Attaches metal to metal.

Size Pt Bulk Part No Bulk Qty Lbs* Drill Cap (in.) 5lb Part No 5lb Qty 1lb Part No 1lb Qty
8-18 x 1/2 2 F82 10M 25 .035 – .100 F82V 2,000 F82I 400
8-18 x 3/4 2 F83 10M 35 .035 – .100 F83V 1,500 F83I 300
8-18 x 1 2 F84 8M 34 .035 – .100 F84V 1,200 F84I 250
8-18 x 1-1/4 2 F85 5M 26 .035 – .100 F85V 1,000 F85I 200
8-18 x 1-1/2 2 F86 5M 31 .035 – .100 F86V 800 F86I 150
10-16 x 3/4 3 F106 8M 39 .035 – .176 F106V 1,000 F106I 200
10-16 x 1 3 F108 5M 32 .035 – .176 F108V 800 F108I 150
10-16 x 1-1/4 3 F109 4M 31 .035 – .176 F109V 650 F109I 125
10-16 x 1-1/2 3 F110 4M 37 .035 – .176 F110V 500 F110I 100
10-16 x 2 3 F116 3M 35 .035 – .176 F116V 500 F116I 100
10-16 x 2-1/2 3 F120 1.5M 20 .035 – .176 F120V 400 F120I 80
10-16 x 3 3 F124 1M 17 .035 – .176 F124V 300 F124I 60
12-14 x 1 3 F208 4M 30 .035 – .210 F208V 650 F208I 125
12-14 x 1-1/2 3 F212 3M 35 .035 – .210 F212V 450 F212I 90
12-14 x 2 3 F216 2M 32 .035 – .210 F216V 300 F216I 60
12-14 x 3 3 F224 1M 20 .035 – .210 F224V 250 F224I 50
14-14 x 1 3 F408 3M 42 .060 – .220 F408V 350 F408I 70
14-14 x 1-1/2 3 F412 2M 36 .060 – .220 F412V 250 F412I 50
14-14 x 2 3 F416 1.5M 35 .060 – .220 F416V 200 F416I 40
14-14 x 3 3 F424 1M 30 .060 – .220 F424V 150 F424I 30
*Carton weights are approximate and may vary.

Features

  • For counter-sunk holes

Specifications

  • Meets ASTM C 1513 for cold-formed steel framing connections
  • Meets F.I.P.-1000.7 for torsional strength & drill speed
  • Manufactured to SAE J78 for dimensional specifications
  • Meets ASTM A 510 for carbon steel manufacturing
  • Meets ASTM F1941 for corrosion resistance

Test Results

Pullout Values (Avg. Lbs.)
Fastener Steel Gauge
Size Pt 20 18 16 14 12 1/8 3/16 1/4
8-18 2 292 479 685 933
10-16 3 293 487 690 941 1432 2017
Shear Values (Avg. Lbs.)
Fastener Steel Gauge (Lapped)
Size Pt 20 18 16 14 12 1/8 3/16 1/4
8-18 2 721 1031 1049
10-16 3 709 1231 1497 1508
The values listed are averages achieved under laboratory conditions and imply no warranty. Appropriate safety factors should be applied to these values for design purposes.