Phillips Flat Head Reamer w/Wings, Zinc Plated

Material Application: Attaches wood to metal.

Recess Type:
Phillips

Head Type:
Flat Head

Coating:
Zinc

Where to Buy:

Size Pt Bulk Part No Bulk Qty Lbs* Drill Cap (in.) Wood Range Submittal
10-16 x 1-5/8 3 R158 4M 36 .060 – .176 1/4” – 7/8” View
12-24 x 2 3 R200 2M 32 .110 – .210 1/2” – 1-1/8” View
12-24 x 2-1/4 3 R214 1.5M 27 .110 – .210 1/2” – 1-3/8” View
12-24 x 2-1/2 3 R2123 1.5M 30 .110 – .210 1/2” – 1-5/8” View
12-24 x 2-1/2 4 R212 1.5M 30 .110 – .250 1/2” – 1-1/2” View
1/4-20 x 2-3/4 4 R234 1M 30 .110 – .375 3/4” – 1-3/4” View
1/4-20 x 3-1/4 4 R314 1M 35 .110 – .375 3/4” – 2-1/4” View
1/4-20 x 3-1/2 4 R312 .8M 30 .110 – .375 3/4” – 2-1/2” View
1/4-20 x 3-3/4 4 R334 .5M 20 .110 – .375 3/4” – 2-3/4” View

*Carton weights are approximate and may vary.

Size 5lb Part No 5lb Qty 1lb Part No 1lb Qty Submittal
10-16 x 1-5/8 R158V 500 R158I 100 View
12-24 x 2 R200V 300 R200I 60 View
12-24 x 2-1/4 R214V 250 R214I 50 View
12-24 x 2-1/2 N/A N/A N/A N/A View
12-24 x 2-1/2 R212V 250 R212I 50 View
1/4-20 x 2-3/4 R234V 160 R234I 30 View
1/4-20 x 3-1/4 R314V 150 R314I 30 View
1/4-20 x 3-1/2 R312V 130 R312I 25 View
1/4-20 x 3-3/4 R334V 125 R334I 25 View
  • Wings ream hole in wood preventing “jacking action”
  • Used for attaching lumber or headers to steel
  • Meets ASTM C 1513 for cold-formed steel framing connections
  • Meets F.I.P.-1000.7 for torsional strength & drill speed
  • Manufactured to SAE J78 for dimensional specifications
  • Meets ASTM A 510 for carbon steel manufacturing
  • Meets ASTM F1941 for corrosion resistance
Pullout Values (Avg. Lbs.)
Fastener Steel Gauge
Size Pt 20 18 16 14 12 1/8 3/16 1/4
10-16 3 293 487 690 941 1432 2017
12-24 3 484 679 959 1489 2371 3384 3732
12-24 4 484 679 959 1489 2371 3384 3732
1/4-20 4 595 856 1114 1805 2337 4416 4885
Shear Values (Avg. Lbs.)
Fastener Steel Gauge (Lapped)
Size Pt 20 18 16 14 12 1/8 3/16 1/4
10-16 3 709 1231 1497 1508
12-24 3 1989 1972
12-24 4 1989 1972
1/4-20 4 2040 2509 2573 2738
The values listed are averages achieved under laboratory conditions and imply no warranty. Appropriate safety factors should be applied to these values for design purposes.