Material Application: Attaches metal to metal.
Recess Type:
Unslotted Indented Hex
Head Type:
Hex Washer Head
Coating:
Strong-Shield
Where to Buy:
Bulk Products
Size | Pt | Bulk Part No | Bulk Qty | Lbs* | Drill Cap (in.) | Submittal |
12-24 x 1-1/4 | 5 | H5C | 3.5M | 39 | .125 – .500 | View |
12-24 x 1-1/2 | 5 | H52C | 2.5M | 33 | .125 – .500 | View |
12-24 x 2 | 5 | H53C | 2M | 33 | .125 – .500 | View |
12-24 x 3 | 5 | H54C | 1M | 23 | .125 – .500 | View |
1/4-20 x 3 | 5 | H543C | 1M | 34 | .125 – .500 | View |
1/4-20 x 4 | 5 | H544C | .5M | 22 | .125 – .500 | View |
1/4-20 x 5 | 5 | H545C | .5M | 26 | .125 – .500 | View |
1/4-20 x 6 | 5 | H546C | .5M | 31 | .125 – .500 | View |
1/4-20 x 8 | 5 | H548C | .25M | 20 | .125 – .500 | View |
*Carton weights are approximate and may vary.
Packaged Product
Size | 5lb Part No | 5lb Qty | 1lb Part No | 1lb Qty | Submittal |
12-24 x 1-1/4 | H5CV | 400 | H5CI | 100 | View |
12-24 x 1-1/2 | H52CV | 400 | H52CI | 80 | View |
12-24 x 2 | H53CV | 300 | H53CI | 60 | View |
12-24 x 3 | H54CV | 200 | H54CI | 40 | View |
1/4-20 x 3 | H543CV | 150 | H543CI | 30 | View |
1/4-20 x 4 | H544CV | 100 | H544CI | 20 | View |
1/4-20 x 5 | H545CV | 100 | H545CI | 20 | View |
1/4-20 x 6 | H546CV | 75 | H546CI | N/A | View |
1/4-20 x 8 | H548CV | N//A | H548CI | N/A | View |
Specifications
- Meets ASTM C 1513 for cold-formed steel framing connections
- Meets F.I.P.-1000.7 for torsional strength & drill speed
- Manufactured to SAE J78 for dimensional specifications
- Meets ASTM A 510 for carbon steel manufacturing
Test Results
Pullout Values (Avg. Lbs.) | |||||||||
Fastener | Steel Gauge | ||||||||
Size | Pt | 20 | 18 | 16 | 14 | 12 | 1/8 | 3/16 | 1/4 |
12-24 | 5 | 475 | 672 | 951 | 1486 | 2269 | 3393 | 3882 | |
1/4-20 | 5 | 595 | 856 | 1114 | 1805 | 2337 | 4416 | 4885 |
Shear Values (Avg. Lbs.) | |||||||||
Fastener | Steel Gauge (Lapped) | ||||||||
Size | Pt | 20 | 18 | 16 | 14 | 12 | 1/8 | 3/16 | 1/4 |
12-24 | 5 | 2622 | 2641 | 2682 | |||||
1/4-20 | 5 | 2738 | 2842 | 3019 | |||||
The values listed are averages achieved under laboratory conditions and imply no warranty. Appropriate safety factors should be applied to these values for design purposes. |