Phillips Modified Truss (R/W) Head, Zinc Plated

Material Application: Attaches wire lath to metal studs or metal to metal.

Recess Type:
Phillips

Head Type:
Modified Truss Head

Coating:
Zinc

Where to Buy:

Size Pt Bulk Part No Bulk Qty Lbs* Drill Cap (in.) Submittal ICC
8-18 x 1/2 2 M82Z 10M 37 .035 – .100 View View
8-18 x 3/4 2 M83Z 8M 37 .035 – .100 View View
8-18 x 1 2 M84Z 5M 28 .035 – .100 View View
8-18 x 1-1/4 2 M85Z 5M 34 .035 – .100 View View
8-18 x 1-5/8 2 M87Z 4M 32 .035 – .100 View View
8-18 x 1-7/8 2 M88Z 2M 18 .035 – .100 View View
8-18 x 2-1/2 2 M92Z 2M 23 .035 – .100 View View
8-18 x 3 2 M95Z 1.5M 20 .035 – .100 View View
10-16 x 3/4 3 M106Z 7M 38 .035 – .176 View View
10-16 x 4 3 M1032Z 1M 20 .035 – .176 View
12-14 x 3/4 3 M126Z 4M 25 .035 – .210 View View

*Carton weights are approximate and may vary.

Size 5lb Part No 5lb Qty 1lb Part No 1lb Qty Submittal
8-18 x 1/2 M82ZV 1,300 M82ZI 300 View
8-18 x 3/4 M83ZV 1,000 M83ZI 200 View
8-18 x 1 M84ZV 800 M84ZI 200 View
8-18 x 1-1/4 M85ZV 700 M85ZI 150 View
8-18 x 1-5/8 M87ZV 600 M87ZI 125 View
8-18 x 1-7/8 M88ZV 500 M88ZI 100 View
8-18 x 2-1/2 M92ZV 400 M92ZI 80 View
8-18 x 3 M95ZV 375 M95ZI 75 View
10-16 x 3/4 M106ZV 1,000 M106ZI 200 View
10-16 x 4 M1032ZV 200 M1032ZI 50 View
12-14 x 3/4 M126ZV 800 M126ZI 160 View

  • Meets ASTM C 1513 for cold-formed steel framing connections
  • Meets F.I.P.-1000.7 for torsional strength & drill speed
  • Manufactured to SAE J78 for dimensional specifications
  • Meets ASTM A 510 for carbon steel manufacturing
  • Meets ASTM F1941 for corrosion resistance
  • ICC-ES Evaluation Report: ESR-3528
Pullout Values (Avg. Lbs.)
Fastener Steel Gauge
Size Pt 20 18 16 14 12 1/8 3/16 1/4
8-18 2 292 479 685 933
10-16 3 293 487 690 941 1432 2017
12-14 3 737 1034 1585 2349 2911
Shear Values (Avg. Lbs.)
Fastener Steel Gauge (Lapped)
Size Pt 20 18 16 14 12 1/8 3/16 1/4
8-18 2 721 1031 1049
10-16 3 709 1231 1497 1508
12-14 3 749 1320 1574 1914 1929
The values listed are averages achieved under laboratory conditions and imply no warranty. Appropriate safety factors should be applied to these values for design purposes.